---
title: Calibración en Polyworks
description: "Calibración de palpadores en Polyworks: Asegúrate de seguir el proceso correcto de calibración de las herramientas de palpado."
image: https://www.appscmm.com/hubfs/Portadas_blog_15.png
---

[Skip to content](https://www.appscmm.com/blog/calibracion-polyworks#main-content)

[![Logo Aplicaciones-CMM](https://www.appscmm.com/hs-fs/hubfs/Logo%20Aplicaciones-CMM.png?width=133&height=50&name=Logo%20Aplicaciones-CMM.png "Logo Aplicaciones-CMM")](https://www.appscmm.com/)

- [Inicio](https://www.appscmm.com)
- [GD&T](https://www.appscmm.com/gdt)
- [Programación](https://www.appscmm.com/programacion)
- [Calibración](https://www.appscmm.com/calibracion)
- [Renta CMM](https://www.appscmm.com/renta-cmm)
- [Cursos](https://www.appscmm.com/cursos)
- [Blog](https://www.appscmm.com/blog)
- [Contacto](https://www.appscmm.com/contacto)

- [Polyworks](https://www.appscmm.com/blog/tag/polyworks),
- [CMM](https://www.appscmm.com/blog/tag/cmm)

# Calibración en Polyworks

![](https://www.appscmm.com/hubfs/Portadas_blog_15.png)

- julio 27, 2023

![Carlos Mares](https://www.appscmm.com/hubfs/user.jpeg)

[Carlos Mares](https://www.appscmm.com/blog/author/carlos-mares)

El proceso de calibración de palpadores es uno de los procesos fundamentales previos al uso de la maquina de medición por coordenadas (CMM), dependiendo de lo critico del proceso o el procedimiento se puede realizar hasta una vez cada turno.

## Esfera de referencia

La esfera se utiliza como punto de referencia para asegurar la precisión y exactitud de las mediciones realizadas por los palpadores. La esfera de referencia se coloca estratégicamente en la CMM y se utiliza para verificar la alineación y la corrección de cualquier desviación en los palpadores. Es crucial calibrar regularmente los palpadores para garantizar la confiabilidad de las mediciones y la calidad de los resultados obtenidos.

La información de la esfera se ubica en la barra inferior del software, en las propiedades del dispositivo (primer icono):

![barra_dispositivo](https://www.appscmm.com/hs-fs/hubfs/barra_dispositivo.png?width=600&height=81&name=barra_dispositivo.png)

Dentro de las propiedades, la esfera de referencia se ubica en la primer pestaña:

![ventana_config_polyw](https://www.appscmm.com/hs-fs/hubfs/ventana_config_polyw.png?width=635&height=400&name=ventana_config_polyw.png)

La información significativa previo a calibrar es verificar los valores de:

1. Diámetro (acorde al certificado de calibración).
2. Diámetro del vástago de la esfera.
3. Orientación (vectores i,j,k)

Para validar la esfera, seleccionar esfera, clic derecho editar; de no contar aun con una, seleccionar crear y agregar la información. Se cierra la ventana y posteriormente ir al icono para localizar la esfera![locate_sphere](https://www.appscmm.com/hs-fs/hubfs/locate_sphere.png?width=51&height=50&name=locate_sphere.png).

La localización permite ubicar la esfera en el espacio de medición de la CMM. Al seleccionar, se abre la ventana:

![locate_sphere_cnc](https://www.appscmm.com/hs-fs/hubfs/locate_sphere_cnc.png?width=285&height=400&name=locate_sphere_cnc.png)

Designar los parámetros con los que se realzara la calibración, información de la esfera, palpado, distancia de búsqueda y retracción. Una vez este ubicada la esfera se proba realizar la calibración de los palpadores y posiciones que se requieran en la medición.

## Herramientas

Las herramientas (tools) de palpado, se ubican en la ventana de propiedades del dispositivo, segunda pestaña, donde se pueden agregar, editar o eliminar las herramientas.

![Ventana_tools](https://www.appscmm.com/hs-fs/hubfs/Ventana_tools.png?width=635&height=400&name=Ventana_tools.png)

Al seleccionar el icono de ![Tools_ori](https://www.appscmm.com/hs-fs/hubfs/Tools_ori.png?width=41&height=50&name=Tools_ori.png)se mostraran las herramientas y sus orientaciones en la siguiente ventana:

![tools_ori_lista](https://www.appscmm.com/hs-fs/hubfs/tools_ori_lista.png?width=800&height=178&name=tools_ori_lista.png)

La vista principal es en forma de lista, la segunda vista es mediante la rejilla, la cual es muy util para crear nuevas orientaciones de las herramientas.

![tools_ori_grid](https://www.appscmm.com/hs-fs/hubfs/tools_ori_grid.png?width=800&height=331&name=tools_ori_grid.png)

La vista de rejilla muestra todos los ángulos disponibles que se pueden seleccionar.

## Calibración

Desde las opciones disponibles desplegadas por el icono de herramientas y orientaciones, se realiza la calibración. Primero se selecciona el o los ángulos de alguna de las pestañas y se selecciona el icono de ![calibrar_polyw](https://www.appscmm.com/hs-fs/hubfs/calibrar_polyw.png?width=55&height=50&name=calibrar_polyw.png). Lo que despliega la ventana:

![ventana_cali_poly](https://www.appscmm.com/hs-fs/hubfs/ventana_cali_poly.png?width=245&height=400&name=ventana_cali_poly.png)

Se definen los parámetros casi idénticos que los disponibles para la localización de la esfera de referencia. Los datos sobre los estados de las herramientas se componen de tres. 

![ventana_estatus_polyw](https://www.appscmm.com/hs-fs/hubfs/ventana_estatus_polyw.png?width=613&height=400&name=ventana_estatus_polyw.png)

Si la calibración fue exitosa la orientación se coloca con una palomita de verificación, si hubo un error o no esta calibrada, con un triangulo de advertencia y si esta seleccionado un ángulo se ilumina el recuadro.

[![Share on facebook](https://7528309.fs1.hubspotusercontent-na1.net/hub/7528309/hubfs/raw_assets/public/mV0_d-web-default-modules_hubspot/img/facebook-color.png?width=24&name=facebook-color.png)](http://www.facebook.com/share.php?u=https%3A%2F%2Fwww.appscmm.com%2Fblog%2Fcalibracion-polyworks%3Futm_medium%3Dsocial%26utm_source%3Dfacebook) [![Share on linkedin](https://7528302.fs1.hubspotusercontent-na1.net/hub/7528302/hubfs/raw_assets/public/mV0_d-web-default-modules_hubspot/img/linkedin-color.png?width=24&name=linkedin-color.png)](http://www.linkedin.com/shareArticle?mini=true&url=https%3A%2F%2Fwww.appscmm.com%2Fblog%2Fcalibracion-polyworks%3Futm_medium%3Dsocial%26utm_source%3Dlinkedin) [![Share on twitter](https://7528302.fs1.hubspotusercontent-na1.net/hub/7528302/hubfs/raw_assets/public/mV0_d-web-default-modules_hubspot/img/x-twitter-color.png?width=24&name=x-twitter-color.png)](https://twitter.com/intent/tweet?original_referer=https%3A%2F%2Fwww.appscmm.com%2Fblog%2Fcalibracion-polyworks%3Futm_medium%3Dsocial%26utm_source%3Dtwitter&url=https%3A%2F%2Fwww.appscmm.com%2Fblog%2Fcalibracion-polyworks%3Futm_medium%3Dsocial%26utm_source%3Dtwitter&source=tweetbutton&text=)

 Publicaciones

## Otros artículos

Otras publicaciones que pueden ser de tu interés. Descubre mas temas relaciones a GD&T y programación.

[![](https://www.appscmm.com/hubfs/PortadaBlog_39.png)](https://www.appscmm.com/blog/modos-calibracion)

[Calypso](https://www.appscmm.com/blog/tag/calypso), [CMM](https://www.appscmm.com/blog/tag/cmm)

### [Modos de calibración](https://www.appscmm.com/blog/modos-calibracion)

 diciembre 7, 2024

 La calibración de los palpadores en una Máquina de Medición por Coordenadas (CMM) es un proceso crucial para asegurar...

[Leer más](https://www.appscmm.com/blog/modos-calibracion)

[![](https://www.appscmm.com/hubfs/Portadas%20Blog-19.png)](https://www.appscmm.com/blog/orientacion-esfera-vectores)

[PC-DMIS](https://www.appscmm.com/blog/tag/pc-dmis), [Polyworks](https://www.appscmm.com/blog/tag/polyworks), [CMM](https://www.appscmm.com/blog/tag/cmm)

### [Orientación de la esfera de referencia](https://www.appscmm.com/blog/orientacion-esfera-vectores)

 agosto 3, 2023

 Determinar la posición y orientación de la esfera de referencia es de los primeros pasos previo a calibrar los...

[Leer más](https://www.appscmm.com/blog/orientacion-esfera-vectores)

[![Valores límite, calibración](https://www.appscmm.com/hubfs/Portadas_Blog09.png)](https://www.appscmm.com/blog/valores-limite)

[Calypso](https://www.appscmm.com/blog/tag/calypso), [Mediciones](https://www.appscmm.com/blog/tag/mediciones)

### [Valores límite](https://www.appscmm.com/blog/valores-limite)

 julio 3, 2023

 Los valores límite son valores que permiten establecer un criterio y determinar si la calibración de un palpador es...

[Leer más](https://www.appscmm.com/blog/valores-limite)

[Ver todas las publicaciones](https://www.appscmm.com/blog)

### Soporte / asesoría

Deja tu comentario, si tienes alguna duda adicional puedes enviarnos un mensaje mediante el formulario de contacto.

[![Logo Aplicaciones-CMM](https://www.appscmm.com/hs-fs/hubfs/Logo%20Aplicaciones-CMM.png?width=133&height=50&name=Logo%20Aplicaciones-CMM.png "Logo Aplicaciones-CMM")](https://www.appscmm.com/)

Aplicaciones CMM es un proyecto enfocado en el desarrollo, capacitación y formación de nuevos programadores. 

Esto es un campo de búsqueda con una función de texto predictivo.

- No hay sugerencias porque el campo de búsqueda está vacío.

### Paginas

- [Inicio](https://www.appscmm.com)
- [GD&T](https://www.appscmm.com/gdt)
- [Programación](https://www.appscmm.com/programacion)
- [Calibración](https://www.appscmm.com/calibracion)
- [Cursos](https://www.appscmm.com/cursos)
- [Crear programa](https://www.appscmm.com/crear-programa)

#### Blog

- [Publicaciones](https://www.appscmm.com/blog)

#### Contacto

- [Datos de contacto](https://www.appscmm.com/contacto)

---

- [Términos y condiciones](https://www.appscmm.com/terminos-y-condiciones)
- [Política de privacidad](https://www.appscmm.com/aviso)

[Síguenos en Facebook](https://www.facebook.com/especialistaCMM/) [Contáctanos en WhatsApp](https://wa.me/message/J36RDHRYRGOFP1) [Follow us on Facebook](https://www.instagram.com/especialistas_cmm) [Follow us on Facebook](https://www.linkedin.com/company/especialistas-en-cmm/)

```json
{
  "@context" : "https://schema.org",
  "@type" : "BlogPosting",
  "author" : {
    "@type" : "Person",
    "name" : "Carlos Mares",
    "url" : "https://www.appscmm.com/blog/author/carlos-mares"
  },
  "dateModified" : "2024-04-03T17:21:04.071Z",
  "datePublished" : "2023-07-27T03:35:44.000Z",
  "headline" : "Calibración en Polyworks",
  "image" : [ "https://www.appscmm.com/hubfs/Portadas_blog_15.png" ],
  "mainEntityOfPage" : {
    "@id" : "https://www.appscmm.com/blog/calibracion-polyworks",
    "@type" : "WebPage"
  },
  "publisher" : {
    "@type" : "Organization",
    "logo" : {
      "@type" : "ImageObject",
      "url" : "https://www.appscmm.com/hubfs/Logo%20Aplicaciones-CMM-1.png"
    },
    "name" : "Aplicaciones CMM"
  }
}
```